Full Turbine Roving Hammer Test-UW Madison
Test Information
This test was performed in early January 2012
Two sets of measurement were taken with separate accelerometer positions.
The hammer was roved over approximately 60 points on the structure to obtain a fairly dense pattern of points, primarily on the blades. The span of the test was 0 to 800 Hz.
Due to a hardware limitation of 4 channels (3 accelerometers and 1 hammer) per test, the data was taken in two sets, using a total of 6 accelerometer locations. The accelerometers were placed off-center (to capture blade torsion) near the tips of the blades, and on the turbine nacelle. B+K Pulse Labshop software was used for data acquisition.
Photos
Data and Geometry
All data sets are in the universal file format. Use WinRAR or similar to decompress the Dataset Files
Geometry File | Dataset 1 | Dataset 2